Cat Switchgear

Switchgear and Paralleling Controls

Details

Configuration
IP4X

Operating Temperature
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)

Standard Widths
600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

Cat Paralleling Switchgear is the perfect complement for the control and distribution of your emergency power. Modular and Customizable, it can be designed with protection and control architecture.

Benefits

Footprint Savings

Utilizing Unique Systems Level architecture designs

None

Indoor, outdoor & arc resistant designs

Control and Information at your fingertips

Systemwide data integration, graphical representation and available connection to site BMS systems for access to all emergency power system status and alarms.

Features at a Glance

Cat Switchgear
  • Independently certified to meet IEC 61439-2:2011 BS & international standard.
  • Standard ACB breaker range 1600A - 4000A CE & EAC marked.
  • Standard breaker fault rating 65 kA Icc, option for 100kA Icc ABB Emax 2 E4.
  • Certified assembly high fault rating, tested up to 100 kA / 1s ICW
  • Certified standard temperature rise tested.
  • Design verification to Annex D of IEC 61439-2:2011
  • Smaller footprint matched to the generator packaged design.
  • Innovative cableway management.
  • Modularity:
  • Built around 150mm modules in 3 axis.
  • Framework utilises a 25mm grid allowing a fully configurable system.
  • Easy to extend and upgrade.
  • Copper HDHC:
  • Standard 10mm copper with 10mm spacing improves heat rejection.
  •     Stainless steel mounted busbar supports, reduce eddy currents.
  • Fully tinned option.
  • Breaker options:
  • Accommodates fixed or withdrawable breakers.
  • 3 or 4 pole option.
  • Manual or motorized option.
  • ACB door selection option.
  • Enclosure options: o    Options up to Form 4b separation.
  • Configurable for top or bottom entry.
  • Swivel lifting eye (4 point lift) for single sections.
  • IP54 protection option.
  • 50 °C option.
  • Option to include generator controllers or PLC.
  • EPD white powder coated, option for custom colours.
  • In house automated routine testing.
  • Rating plate.
  • Cat warranty.

Specifications

Full Specifications

Enclosure Rating

Configuration
IP4X

Operating Temperature

Operating Temperature
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)

Dimensions

Standard Widths
600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.

Standard Heights
Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping

Standard Depths
300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers

Technical Summary

Technical Summary
Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.

Application

Application
LV 380…480 VAC, 50 Hz, 3-Phase.

Modes of Operation

Modes of Operation
Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc.

Similar New Power Solutions

EMCP 4.4 Master Control Panel
Switchgear and Paralleling Controls

EMCP 4.4 Master Control Panel

Configuration: Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
Modes of Operation: Emergency standby, island, utility paralleling
Application: LV and MV (208V - 38 kV)

Engine Paralleling and Integration Control (EPIC)
Switchgear and Paralleling Controls

Engine Paralleling and Integration Control (EPIC)

Configuration: Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
Modes of Operation: Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
Application: LV and MV (208V-27kV)

Cat XLM Switchgear
Switchgear and Paralleling Controls

Cat XLM Switchgear

Configuration: Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
Modes of Operation: Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
Application: LV and MV ( 208V - 38 kV

Cat EGP Switchgear
Switchgear and Paralleling Controls

Cat EGP Switchgear

Configuration: Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation: Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application: LV and MV (208V - 38 kV)

Cat Customizable Switchgear and Controls
Switchgear and Paralleling Controls

Cat Customizable Switchgear and Controls

Configuration: Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation: All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical power needs
Application: LV and MV ( 208V - 38 kV) 50 / 60 Hz