Cat EGP Switchgear
Switchgear and Paralleling Controls
Details
Configuration
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation
Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application
LV and MV (208V - 38 kV)
Overview
Caterpillar offers standard Switchgear products, which can support a wide variety of applications, or provide a custom designed system to meet your specific project needs. The Emergency Generator paralleling (EGP) product supports paralleling on an isolated generator bus and is commonly used in prime power or emergency standby systems. Caterpillar Standard Switchgear products provide a solution able to combine all elements of monitoring and control for Caterpillar generator sets in a single-source package. Caterpillar also designs and manufacturers custom switchgear to meet specific customer requirements and functionality.
Benefits
Automatic operation
Dead Bus coordination, Load Shed/Load Add functions/ Load-No load Test
Reduced Commissioning Times
High-speed network connections to Caterpillar Generator Set
Flexible Power offerings
UL 891, UL1558, ANSI37.20 -Indoor, Outdoor, E-house
Features at a Glance
- EGP Switchgear
-
- High Speed Supervisory Network
- Automatic Start/Stop
- Automatic “Dead Bus” Coordination
- Programmable Load Shed / Load Add Functions
- Networked Engine Communications
- Generator Protection
- Engine Tuning
- Mode Selection
- Selectable Auto/ Manual Control
- Password Protection for Protective Settings and Setup
- Load/No Load Test
- Touch Screen (HMI) Display
- NFPA 99/110 Compliant Alarm
- Annunciation with Audible Horn
- Engine Control mimic Screen with gauges for RPM, DC Battery Voltage oil Pressure, Engine Coolant temperature, Engine Hours, Number of starts
Specifications
Full Specifications
- Technical Summary
-
Configuration
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applicationsModes of Operation
Multi-unit Island and multi-unit standby mode with optional redundant controls and components.Application
LV and MV (208V - 38 kV)
- Generator Protective Devices
-
ANSI Protective Devices
15/25, 27/59, 81 O/U, 32, 40, 50, 51
- Environmental Parameters
-
Certifications
IBC, CBC, UBC & OSHPD CertifiedControl Panel Enclosure
NEMA 1 or NEMA 3R Freestanding ConstructionOperating Temperature
0°C to 50°CStorage Temperature
-20°C to +60°CLow Voltage Standards
NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70Medium Voltage Standards
NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
Equipment
- Standard Equipment
-
EGP Switchgear
- Choice of 19” Surface Acoustic Wave Color or 15” Resistive Color Touchscreen
- Emergency Stop Button for each generator
- Instant Auto Switch
- Generator Demand Priority Control
- Audible Alarm & Horn Silence Button
- Circuit Breaker Control Switch with Indicators
- Optional Equipment
-
Data Table Interface
- * Accomodates interface with a building management system for monitoring all system parameters via Modbus RTU or TCP
Supplemental Hardware Synchronization check relay (ANSI 25 Device)
- * Provides additional discrete synchronization protection
Remote Power Monitoring System
- * To monitor breaker status, alarms, metering and other operating parameters