XQ230 Rental Power

Mobile Generator Sets

Details

Rating Prime
182 ekW (228 kVA)

Frequency
60 Hz

Voltage
120 - 600 V

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

228 kVA Mobile Diesel Generator Set

The Cat XQ230 is powered by a C 7.1 Tier 4 Final compliant industrial diesel engine offering the perfect balance of durability, efficiency and low emissions. With advanced research and development techniques, the after treatment system is precisely matched to the engine ensuring performance is optimized for maximum productivity.

Benefits

Battery isolator switch

Eliminates battery draindown when generator set is not in operation

and external fuel ports

Easily switch between onboard and external fuel source for extended run times

switch for easy selection of desired output

Eliminates the need for reconnection to meet on-site requirements

Features at a Glance

Rental ready. Retail Optimized (Option)
Robust, durable product with a range of rental ready features to meet job requirements and applications. Option for open genset to meet retail customer needs.
Fuel/Emissions Strategy
Meets U.S. EPA Tier 4 Final emission standards and CARB certified for non-road mobile applications at all 60 Hz ratings
Cat C7.1 Diesel Engine
Industry proven reliability
CAT EMCP4.2B digital controls
Easy to use digital controls
Cat LC Series Generator
Integrated voltage regular for fast response in demanding applications
Sound Isolated Operator panel
Improved operator comfort
Cat Connect
Remote monitoring for fleet management and asset tracking
Factory designed, built and tested
Single-source Supplier
World Wide Product Support
Supported by an industry leading global dealer network
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Improved transportability
Lifting frame, 4 point lift and trailers
Power Distribution
Distribution sockets
Additional options
Synchronising controls.
Extended Service interval kits
600V generator
208V 3-phase NEMA Sockets
Retail Optimised
Option for open genset to meet Retail customer needs

Specifications

Full Specifications

Generator Set

Rating Prime
182 ekW (228 kVA)

Frequency
60 Hz

Voltage
120 - 600 V

Rating Standby
200 ekW (250 kVA)

Engine

Engine
Cat C7.1

Fuel
Diesel

Dimensions

Height - Without Trailer
78.5 in

Length - Without Trailer
162.2 in

Width - Without Trailer
62.8 in

Weight with Lube Oil and Coolant, Without Trailer
8432 lb

Fuel Consumption

100% Load 60Hz
14.7 gal/hr

75% Load 60Hz
10.8 gal/hr

50% Load 60Hz
7.4 gal/hr

Noise rating (with enclosure)

Sound Power @ 7 meters (23 feet) @ All Ratings
72 dB(A)

Equipment

Standard Equipment

CAT C7.1 Diesel Engine

  • Heavy-duty.
    Turbocharged.
    After treatment

Generator

  • LC5034H Frame

Control Panel

  • Digital EMCP4.2B set mounted controller

Cat Connect remote monitoring

  • Provides package monitoring and management

Cooling System

  • Package mounted radiator with vertical air discharge.
    Filled from factory

Charging / Starting System

  • 12V heavy duty starting motor and charging alternator c/w battery isolator

Fuel System

  • 24 hour dual wall fuel tank with 3 way directional valve for external supply

Air Filter

  • Cyclonic/paper with dust cup and service indicator

Distribution

  • Single, robust enclosure for controls and distribution c/w 4 pole circuit breaker and safety cut off

Structure

  • Heavy Duty steel base frame with integral fuel tank.
    Lifting frame and 4 point lift.
    base frame is wider than enclosure to protect generator set during transportation

Enclosure

  • Sound attenuating, galvanised steel enclosure with exceptional noise reduction performance

Exhaust

  • Integrated spark arresting silencer

Lube Oil

  • On engine primary and secondary oil filters. Filled from factory

General

  • Factory tested and inspected

Similar New Power Solutions

XQ425
Mobile Generator Sets

XQ425

Rating Prime: 340 ekW (425 kVA)
Frequency: 50/60 Hz
Voltage: 120 - 600 V

XQC1200
Mobile Generator Sets

XQC1200

Rating: 1150kW (1438 kVA) Continuous
Frequency: 50/60 Hz
Voltage: 230 - 480 V

XQC1600
Mobile Generator Sets

XQC1600

Rating: 1515 ekW (1893 kVA) Continuous
Frequency: 50/60 Hz
Voltage: 230 - 480 V

XQ570 Tier 4 Final - 455 ekW (568 kVA)
Mobile Generator Sets

XQ570 Tier 4 Final - 455 ekW (568 kVA)

Rating Prime: 455 ekW (568 kVA)
Frequency: 60 Hz
Voltage: 120 - 600 V

XQ35
Mobile Generator Sets

XQ35

Rating Prime: 27 ekW (35 kVA)
Frequency: 60 Hz
Voltage: 120 - 600 V

XQP150
Mobile Generator Sets

XQP150

Rating Prime: 150 kVA
Frequency: 50/60 Hz
Voltage: 127 - 480 V

XQP500
Mobile Generator Sets

XQP500

Rating Prime: 500 kVA
Frequency: 50/60 Hz
Voltage: 127 - 480 V

XQ60
Mobile Generator Sets

XQ60

Rating Prime: 47.5 ekW (60 kVA)
Frequency: 60 Hz
Voltage: 120 - 600 V

XQP300
Mobile Generator Sets

XQP300

Rating Prime: 300 kVA
Frequency: 50/60 Hz
Voltage: 127 - 480 V

XQP100
Mobile Generator Sets

XQP100

Rating Prime: 100 kVA
Frequency: 50/60 Hz
Voltage: 127 - 480 V