XQ1140 T4 Final - Diesel

Mobile Generator Sets

Details

Rating Prime
910 ekW (1136 kVA)

Frequency
60 Hz

Voltage
120 - 600V

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

1000 ekW Mobile Diesel Generator Set

The XQ1140 offers multiple modes of operation to meet your unique needs – even as they change. By incorporating two C18, EPA Tier 4 Final compliant diesel generator sets, this package can provide power output from the generator sets in parallel, N+1 power or independent power from each generator set. That versatility minimizes your operating costs always with the XQ1140 reliability and durability.

Benefits

Tier 4 Final Engines

Twin Pack configuration for full power output or redundancy backup options

Operator Interface

Externally mounted graphical color touch-screen interface for remote start, genset monitoring, breaker operation, and alarm acknowledgements

Fuel & DEF Fill Ports

Same-side curbside access for fuel and DEF fill

Features at a Glance

Rental ready
Robust, durable product with a range of rental ready features to meet job requirements and applications.
Fuel/Emissions Strategy
Meets U.S. EPA Tier 4 Final emission standards and CARB certified for non-road mobile applications at all 60 Hz ratings.
Cat C18 Diesel Engines
Dual Cat C18 ACERT™ heavy-duty diesel engines. Industry proven reliability.
CAT EMCP 4.4 Digital Controls
Dual EMCP 4.4 easy to use digital controls with manual and automatic paralleling capability.
Cat LC Series Generators
Class H Insulation. Integrated voltage regular for fast response in demanding applications.
HMI Controls
Externally Mounted Color Touch-Screen HMI Control Center
Cat Connect
Remote monitoring for fleet management and asset tracking
Sound Attenuated Container
77 dBA @ 7m Sound Performance @ 75% Prime Load. 40' ISO high cube container, 9-high stack CSC certified Service and Personnel doors. Externally-accessible controls
500 hr oil change intervals
Reducing operating costs and producing less waste
Reduced Environmental Impact
110% Spill Containment of On-Board Engine Fluids.
Factory designed, built and tested
Single-source Supplier
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Additional options
Two-axle, air-ride traler with anti-lock brakesystem
Extended Service interval kits
600V generator

Specifications

Full Specifications

Generator Set

Rating Prime
910 ekW (1136 kVA)

Frequency
60 Hz

Voltage
120 - 600V

Rating Standby
1000 ekW (1250 kVA)

Engine

Engine
Cat C18

Fuel
Diesel

Dimensions

Height - Without Trailer
114 in

Length - Without Trailer
480 in

Width - Without Trailer
96 in

Weight with Lube Oil and Coolant, Without Trailer
50107 lb

Fuel Consumption

100% Load 60Hz
66.4 gal/hr

75% Load 60Hz
52.4 gal/hr

50% Load 60Hz
38 gal/hr

100% Load 60Hz
71.8 gal/hr

75% Load 60Hz
56.6 gal/hr

50% Load 60Hz
41 gal/hr

Noise rating (with enclosure)

Sound Power @ 7 meters (23 feet) @ All Ratings
76 dB(A)

Equipment

Standard Equipment

Cat C18 Diesel Engines

  • Two Cat C18 Diesel Engines
  • Reliable, rugged, durable design
  • EPA Tier 4 Final and CARB Emissions Certified
  • Turbocharged Aftercooled
  • Aftertreatment module.
    DEF System

Alternator and Alternator attachments

  • 3 Phase, brushless, 12 lead, Permanent Magnet Excited
  • LC6134G Frame
  • Anti-condensation space heaters
  • Integrated voltage regulator (IVR) with VAR/PF control
  • Sized for 105°C temperature rise at 40°C ambient

Control Panels

  • Dual EMCP 4.4 genset mounted digital controllers
  • Externally accessible Color Touch-Screen HMI Control Center
  • Manual and automatic paralleling capability

Governing system

  • Electrical governing system ADEM™ A4

Cat Connect remote monitoring

  • Provides package monitoring and management

Cooling System

  • Vertically mounted radiator with vertical airdischarge from the container
  • Provides 47°C ambient capability at Prime rating

Charging / Starting System

  • UL Listed and CSA Certified 240V, 20 Amp battery charger
  • Charging alternator; 24V-80A, heavy duty withintegral regulator and belt guards
  • Solar maintainer for batteries
  • Single electric starting motor, 24V per engine

Fuel System

  • 630-gal (2385 L) double-wall fuel tank, UL 142and ULC 601 Listed and complies with Transport Canada requirements, internal and external fuel fill
  • Fuel tanks connected by fuel transfer system withfilter to allow both engines access to all fuel on-board
  • Primary and secondary fuel filters
  • Fuel cooler

Air inlet system

  • Heavy-duty air element, canister type

Distribution

  • Externally accessible, Vibration Isolated, 3600A Frame, 1000 Ka, IC, 3-pole electrically operated breaker with lock out tag out provision
  • Busbar connections
  • Dual customer connections

Sound Attenuated Container

  • 40' ISO high cube container
  • Sound level is 76 dB(A) at 7 meters per SAEJ1074 measured at 75% prime load
  • Sound attenuated air intake louvers and fivelockable personnel doors with panic release

Lube System

  • Pump, integral oil cooler, lube oil, filter, filler and dipstick, and oil sampling valve
  • Oil drain line with internal brass ball valve routedto connection point accessible from exterior

General

  • Factory tested and inspected
  • Full manufacturer's warranty
  • UL, NEMA, ISO, and IEEE standards
Optional Equipment

Trailer

  • Two-axle, air-ride chassis with anti-lock brake system

Similar New Power Solutions

XQ425
Mobile Generator Sets

XQ425

Rating Prime: 340 ekW (425 kVA)
Frequency: 50/60 Hz
Voltage: 120 - 600 V

XQC1200
Mobile Generator Sets

XQC1200

Rating: 1150kW (1438 kVA) Continuous
Frequency: 50/60 Hz
Voltage: 230 - 480 V

XQC1600
Mobile Generator Sets

XQC1600

Rating: 1515 ekW (1893 kVA) Continuous
Frequency: 50/60 Hz
Voltage: 230 - 480 V

XQ570 Tier 4 Final - 455 ekW (568 kVA)
Mobile Generator Sets

XQ570 Tier 4 Final - 455 ekW (568 kVA)

Rating Prime: 455 ekW (568 kVA)
Frequency: 60 Hz
Voltage: 120 - 600 V

XQ35
Mobile Generator Sets

XQ35

Rating Prime: 27 ekW (35 kVA)
Frequency: 60 Hz
Voltage: 120 - 600 V

XQP150
Mobile Generator Sets

XQP150

Rating Prime: 150 kVA
Frequency: 50/60 Hz
Voltage: 127 - 480 V

XQP500
Mobile Generator Sets

XQP500

Rating Prime: 500 kVA
Frequency: 50/60 Hz
Voltage: 127 - 480 V

XQ60
Mobile Generator Sets

XQ60

Rating Prime: 47.5 ekW (60 kVA)
Frequency: 60 Hz
Voltage: 120 - 600 V

XQP300
Mobile Generator Sets

XQP300

Rating Prime: 300 kVA
Frequency: 50/60 Hz
Voltage: 127 - 480 V

XQP100
Mobile Generator Sets

XQP100

Rating Prime: 100 kVA
Frequency: 50/60 Hz
Voltage: 127 - 480 V