Gas Generator G3516H

Gas Generator Sets

Details

Continuous Rating
2027 / 2007 ekW @ 1.0pf

Fuel Type
Natural Gas, Hydrogen Blend (up to 25%)

Maximum Electrical Efficiency
45.30%

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

1419 - 2027 kW Gas Generator

From natural gas to biogas, coal mine gases, or hydrogen fuel blends to support combined heat and power (CHP), emergency power, and local grid support applications, Caterpillar has a wide range of reliable gas power solutions.

Benefits

hydrogen blended fuel option

Enables operation of up to 25% hydrogen blend (by volume) with pipeline natural gas fuel.

savings on service

Extended maintenance intervals leading to lower service costs

Lower lube oil consumption

Leading to lower service costs and extended maintenance intervals

Features at a Glance

Cat G3516H Gas Engine
  • Robust high speed block design provides prolonged life and lower owning operationg costs
  • Designed for maximum performance on low pressure pipeline natural gas and hydrogen mixtures
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
SR5 Generator
  • Designed to match performance and output characteristics of Caterpillar gas engines
  • Industry leading mechanical and electrical design
  • High efficiency
EMCP 4.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Emissions
  • Meets most worldwide emissions requirements down to 0.5 g/bhp-hr NOx level without aftertreatment
Proven System
  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available
Full Range of Attachments
  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Continuous Rating
2027 / 2007 ekW @ 1.0pf

Fuel Type
Natural Gas, Hydrogen Blend (up to 25%)

Maximum Electrical Efficiency
45.30%

Frequency
50 / 60 Hz

RPM
1500 rpm

Engine Specifications

Engine Model
G3516H

Displacement
4765 in³

Aspiration
TA

Bore
6.7 in

Stroke
8.5 in

Compression Ratio
12.1

Fuel System
Natural Gas

Generator Set Dimensions

Length
291 in

Width
84 in

Height
95 in

Dry Weight - Genset
40384 lb

Equipment

Standard Equipment

Control Panels

  • EMCP4.3

Air Inlet

  • Package Mounted Air Cleaner with service indicator
  • Two-element single-stage air cleaner with enclosure and service indicator

Cooling

  • Jacket water and SCAC driven thermostats
  • ANSI Class 150/DN custom flange connections for JW inlet and outlet
  • Engine driven water pumps for jacket water and after cooler
  • 2nd stage SCAC-Cat Flange

Exhaust

  • Center section cooled turbocharger with Cat flanged outlet
  • Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
  • Dry exhaust manifolds, insulated and shielded
  • Cat-flanged face outlet on turbocharger

Fuel System

  • Throttle plate, 24V DC actuator, controlled by GECM
  • Electronic fuel metering valve
  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve

Ignition System

  • Electronic Ignition System (controlled by ADEM A4)
  • Individual Cylinder Detonation Sensitive Timing (DST)

Generator

  • Permanent Magnet Excitiation
  • Anti-condensation space heater
  • Winding temperature detectors
  • SR5
  • Reactive Droop
  • Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control

General

  • Crankshaft vibration damper and guard
  • Paint - Caterpillar Yellow except rails and radiators gloss black
  • RH Service
  • Parts book
  • Operation and maintenance manuals

Governing System

  • ADEM A4 4-20mA (0-5V) Speed Input

Starting/Charging

  • 24V starting motors
Optional Equipment

Air Inlet

  • Mounting brackets and piping
  • Air cleaner with precleaner
  • Heavy Duty air cleaner with precleaner

Circuit Breakers

  • No UV trip or package mounted CB Wiring
  • Frame Mounting
  • MP-Frame 3 Pole Bottom Cable Entry or MP- Frame 6 Pole Bottom Cable Entry
  • 4000A, 3-Pole IEC Rated
  • 2500/3000/3200A or 4000/5000A Neutral Current Transformer Automatic Selection
  • Lower & Upper Covers, Extension Box Roof Cover
  • Busbar Mounting
  • 4000A, 3-Pole UL Rated

Control Panels

  • Remote monitoring software
  • Discrete I/O Module, 12 Digital Inputs, 8 'Form C' Relay
  • Remote RS485, 32-light Annunciator
  • Cat Connect: Ehternet, Satellite, Cell Telematics
  • Cross-Current Compensation Current Transformer-- 8.7/15 kV Classes
  • RTD Module
  • Local/Remote PC Monitorring
  • 16 Point/32 Light Annunciator with NFPA99-110/CSA282 Configuration
  • Remote Monitoring & Control
  • Synchronizing module
  • Local alarm module

Cooling

  • Jacket water coolant heater
  • Inlet/Outlet connections

Exhaust

  • Flange
  • Muffler and spark-arresting muffler with ANSI companion flanges
  • Elbow

Generator

  • Manual voltage control
  • Generator air filter
  • Low voltage extension box
  • Medium and high voltage generators and attachment
  • Cable access box
  • Bearing temperature detectors

Starting/Charging

  • 24V Battery Charger
  • 60A, 24V charging alternator (requires engine driven pumps)

General

  • US AID emblem
  • Special paint order
  • Battery diconnect switch
  • Digital diagnostic tool
  • Tool set
  • Battery with cables and rack (shipped loose)

Grid Code Compliance

  • 60 Hz: USA
  • 50 Hz: Germany, Great Britain, Belgium, Romania, Italy, Ireland, Poland, Netherlands, Spain, France, and European Standard

Similar New Power Solutions

G3520H Gas Generator
Gas Generator Sets

G3520H Gas Generator

Continuous Rating: 2519 / 2500 ekW @ 1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 45.30%

G3512 1000kW Gas Generator Set
Gas Generator Sets

G3512 1000kW Gas Generator Set

Gas Standby Rating: 1000 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

G3512 750kW Gas Generator Set
Gas Generator Sets

G3512 750kW Gas Generator Set

Gas Standby Rating: 750 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

Gas Generator G3512H
Gas Generator Sets

Gas Generator G3512H

Continuous Rating: 1515 ekW / 1505 ekW @1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 44.90%

Cat G3520H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3520H Combined Heat and Power (CHP) Solution

Continuous Rating: 2480 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.40%

Cat G3516H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3516H Combined Heat and Power (CHP) Solution

Continuous Rating: 1982 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.90%

Cat G3512H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3512H Combined Heat and Power (CHP) Solution

Continuous Rating: 1490 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.50%

DG500 (3-Phase)
Gas Generator Sets

DG500 (3-Phase)

Frequency: 60 Hz
Natural Gas Rating: 500 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG100 (60 Hz)
Gas Generator Sets

DG100 (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 100 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency Application

DG125 (Single-phase and 3 phase) (60 Hz)
Gas Generator Sets

DG125 (Single-phase and 3 phase) (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 125 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application