G3516C Gas Generator Set

Gas Generator Sets

Details

Continuous Rating
1660 ekW

Fuel Type
Natural Gas

Maximum Electrical Efficiency
37.70%

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

1173 -1675 kW Natural Gas Generator

From natural gas-fueled combined heat and power (CHP) systems and emergency power for facilities, to renewable biogas energy to support the local grid, or electricity generated from coal mine gases, Caterpillar has a wide range of reliable gas power solutions.

Benefits

Market Leadership

hours Operating Experience

of installations application ranging from Congeneration to Compression

Features at a Glance

Cat G3516C Gas Engine
  • Robust high speed block design provides prolonged life and lower owning operationg costs
  • Designed for maximum performance on low pressure pipeline natural gas
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
SR4B Generator
  • Designed to match performance and output characteristics of Caterpillar gas engines
  • Industry leading mechanical and electrical design
  • High efficiency
EMCP 4.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Emissions
  • Meets most worldwide emissions requirements down to 0.5 g/bhp-hr NOx level without aftertreatment
Proven System
  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available
Full Range of Attachments
  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Continuous Rating
1660 ekW

Fuel Type
Natural Gas

Maximum Electrical Efficiency
37.70%

Maximum Standby Rating
1500

Frequency
50 / 60 Hz

RPM
1500/1800

Engine Specifications

Engine Model
G3516C

Displacement
4210 in³

Aspiration
TA

Bore
6.7 in

Stroke
7.5 in

Generator Set Dimensions

Length
219 in

Width
72 in

Height
92 in

Dry Weight - Genset
31226 lb

Equipment

Standard Equipment

Air Inlet

  • Two-element single-stage air cleaner with enclosure and service indicator

Control Panels

  • EMCP 4.3

Cooling

  • Jacket water and SCAC driven pumps and bypass lines
  • 2nd Stage SCAC-Cat Flange
  • Engine driven water pumps for jacket water and aftercooler
  • Jacket water and SCAC thermostats
  • ANSI/DN customer flange connections for JW inlet and outlet
  • Cat flanges on SCAC circuit

Exhaust

  • Integrated Sensing Module (ISM)
  • Cat-flanged face outlet on turbocharger
  • Provides exhaust port temperatures and stack temperature to customer supplied screen via CCM
  • Dry exhaust manifolds, insulated and shielded

Fuel System

  • 24V ETR Gas Shutoff Valve
  • Engine installed, fuel metering valve
  • Throttle plate, 24V DC actuator, controlled by ECM
  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
  • Fuel Filter

Ignition System

  • Individual Cylinder Detonation Sensitive Timing (DST) 
  • Electronic Ignition System (controlled by ECM) 

Fuel system

  • Electronic fuel metering valve

Generator

  • Anti-condensation space heater
  • Busbar connections
  • Class H Insulation & Class F temperature rise
  • Reactive Droop
  • Permanent Magnet Excitation
  • 3-phase brushless, salient pole
  • Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
  • SR4B
  • Winding temperature detectors

General

  • RH Service
  • Operation and maintenance manuals
  • Crankshaft Vibration Damper and Guard
  • Parts Book

Starting/Charging

  • 24V starting motors
Optional Equipment

Air Inlet

  • Vertical, horizontal dual element air cleaner
  • Enclosure mounting brackets and piping
  • Air cleaner with precleaner

Control Panel

  • Local NFPA99-110 Alarm Module w/LEDs
  • Synchronizing Module
  • Remote 24V 8/16 Light Annunciator
  • Engine Failure Relay
  • PL1000E/PL1000T Communications Module
  • Custom 8-Light Alarm Module

Cooling

  • Inlet/Outlet connections
  • Jacket water coolant heater
  • Aftercooler air lines, aftercooler core replacement

Exhaust

  • Flexible Fittings
  • 14" Flange Kit
  • 406 mm Elbow Kits
  • 406 mm flange kits
  • Mufflers (15/18/25 dBA Attenuation) and spark-arresting muffler with ANSI companion flanges
  • 16" Spark Arresting Muffler
  • 356-406mm Flange and Exhaust Expander
  • 15/18/25 dBA Muffler Attenuation

Fuel System

  • 207-276kPa, 30-40 psi gas knockdown regulator
  • 14-69 kPa (2-10 psi) gas pressure regulator
  • 24VDC Gas Shutoff Valve, Gas Knockdown Regulator
  • Fuel Filter, Gas Filter

Generator

  • Cable access box
  • 8.7/15 kV Cross, Differential, Current Transformers (CCCT, DCT, CT)
  • Medium and high voltage generators and attachment
  • 480/4160/13200 Volt Generator Options (60 Hz)
  • Generator air filter
  • Bearing temperature detectors
  • European Bus Bars
  • 415/400/380, 3300/6600/11000 Volt Generator Options (50 Hz)
  • Annunciator Modules
  • Generator Removal
  • Low voltage extension box

Governing System

  • Load share module

General

  • Special paint order
  • Tool set
  • US AID Emblem
  • Barring group
  • Digital diagnostic tool

Starting/Charging

  • 60A, 24V charging alternator (requires engine driven pumps)
  • Battery removal
  • 20A battery charger
  • Battery disconnect switch
  • Battery with cables and rack (shipped loose)

Similar New Power Solutions

G3520H Gas Generator
Gas Generator Sets

G3520H Gas Generator

Continuous Rating: 2519 / 2500 ekW @ 1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 45.30%

G3512 1000kW Gas Generator Set
Gas Generator Sets

G3512 1000kW Gas Generator Set

Gas Standby Rating: 1000 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

G3512 750kW Gas Generator Set
Gas Generator Sets

G3512 750kW Gas Generator Set

Gas Standby Rating: 750 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

Gas Generator G3512H
Gas Generator Sets

Gas Generator G3512H

Continuous Rating: 1515 ekW / 1505 ekW @1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 44.90%

Cat G3520H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3520H Combined Heat and Power (CHP) Solution

Continuous Rating: 2480 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.40%

Cat G3516H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3516H Combined Heat and Power (CHP) Solution

Continuous Rating: 1982 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.90%

Cat G3512H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3512H Combined Heat and Power (CHP) Solution

Continuous Rating: 1490 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.50%

DG500 (3-Phase)
Gas Generator Sets

DG500 (3-Phase)

Frequency: 60 Hz
Natural Gas Rating: 500 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG100 (60 Hz)
Gas Generator Sets

DG100 (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 100 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency Application

DG125 (Single-phase and 3 phase) (60 Hz)
Gas Generator Sets

DG125 (Single-phase and 3 phase) (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 125 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application