G3512E Gas Generator Set

Gas Generator Sets

Details

Continuous Rating
1200 ekW

Fuel Type
Natural Gas

Maximum Electrical Efficiency
42.30%

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

700 -1200kW Natural Gas Generator

From natural gas-fueled combined heat and power (CHP) systems and emergency power for facilities, to renewable biogas energy to support the local grid, or electricity generated from coal mine gases, Caterpillar has a wide range of reliable gas power solutions.

Benefits

owning & operating cost savings

Higher electrical efficiency paired with extended maintenance intervals increases uptime and reduces costs

Lower lube oil consumption

Leading to lower service costs and extended maintenance intervals

Lower lube oil consumption

Leading to lower service costs and extended maintenance intervals

Features at a Glance

Cat G3512E Gas Engine
  • Robust high speed block design provides prolonged life and lower owning operationg costs
  • Designed for maximum performance on low pressure pipeline natural gas
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
SR4B Generator
  • Designed to match performance and output characteristics of Caterpillar gas engines
  • Industry leading mechanical and electrical design
  • High efficiency
EMCP 4.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cat Electronic Control System
  • Simple user friendly interface and navigation
  • Digital monitoring, metering and protection setting
  • Fully-featured power metering and protective relaying
  • Remote control and monitor capability options
Cooling System
Emissions
  • Meets most worldwide emissions requirements down to 0.5 g/bhp-hr NOx level without aftertreatment
Proven System
  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available
Full Range of Attachments
  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Continuous Rating
1200 ekW

Fuel Type
Natural Gas

Maximum Electrical Efficiency
42.30%

Maximum Standby Rating
-

Frequency
50 Hz

Speed
1500 rpm

Engine Specifications

Bore
6.7 in

Aspiration
TA

Engine Model
G3512E

Stroke
7.5 in

Displacement
3158 in³

Generator Set Dimensions

Length
181 in

Width
65 in

Height
89 in

Dry Weight - Genset
27475 lb

Equipment

Standard Equipment

Air Inlet

  • Two-element single-stage air cleaner with enclosure and service indicator

Control Panel

  • EMCP 4.3

Cooling

  • Jacket water and SCAC engine-driven pumps
  • Jacket water and SCAC thermostats

Exhaust

  • Dry exhaust manifolds, insulated and shielded
  • Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
  • Cat-flanged face outlet on turbocharger

Fuel System

  • Engine-installed electronic control valve
  • 24V DC energized-to-run (ETR) gas shutoff valve
  • Gas pressure regulator

Fuel system

  • Electronic fuel metering valve
  • Throttle plate, 24V DC actuator, controlled by GECM
  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve

General

  • Paint- Caterpillar Yellow except rails are gloss black
  • Parts book
  • Crankshaft vibration damper and guard
  • Operation and maintenance manuals
  • RH Service

Generator

  • SR4B
  • Permanent Magnet Excitiation
  • Caterpillar's Digital Voltage Regulator (CDVR) including reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, and a min/max exciter
  • Anti-condensation space heater
  • Winding temperature detectors
  • NEMA Class H insulation

Governing System

  • ADEM A4

Ignition System

  • Electronic Ignition System (controlled by GECM)
  • Individual Cylinder Detonation Sensitive Timing (DST)

Starting/Charging

  • Electric Starter
Optional Equipment

Air Inlet

  • Mounting brackets and piping
  • Air cleaner with precleaner

Circuit Breakers

  • Frame mounting
  • Right, left, rear mounted
  • 3-pole (IEC 947-2 rated)
  • 100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating
  • S LSI, G LSIG, P LSIG-P, 4th Digit Type
  • 1200A, 3 Pole, UL-100% Rated P-Frame Circuit Breakers
  • 1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers
  • 2000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers

Cooling

  • Remote radiator for JW and SCAC circuits, level switch included but not wired
  • Coolant level drain line with valves, fan with guard
  • Inlet/Outlet connections

Control Panel

  • Local alarm module
  • Remote annunciator
  • Local PC monitoring
  • Remote PC monitoring
  • Engine failure relay

Exhaust

  • 305 mm (12 in.) Flange
  • 250mm-329mm Flange Expander
  • Flexible fittings

Fuel System

  • Remote mounted gas train, sized for 31.5 MJ/Nm3 (800 btu/cu ft) dry pipeline natural gas with inlet pressure range of 19.2 to 48.3 kPa (2.78 to 7 psi).

General

  • US AID emblem
  • Special paint order
  • Tool set
  • Digital diagnostic tool

Generator

  • Cable access box
  • Bearing temperature detectors
  • Generator air filter
  • European bus bars

Starting/Charging

  • 24V starting motors
  • Battery with cables and rack (shipped loose)
  • Jacket water heater
  • 45A, 24V charging alternator (requires engine driven pumps)
  • 20A, 24VDC battery charger

Similar New Power Solutions

G3520H Gas Generator
Gas Generator Sets

G3520H Gas Generator

Continuous Rating: 2519 / 2500 ekW @ 1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 45.30%

G3512 1000kW Gas Generator Set
Gas Generator Sets

G3512 1000kW Gas Generator Set

Gas Standby Rating: 1000 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

G3512 750kW Gas Generator Set
Gas Generator Sets

G3512 750kW Gas Generator Set

Gas Standby Rating: 750 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

Gas Generator G3512H
Gas Generator Sets

Gas Generator G3512H

Continuous Rating: 1515 ekW / 1505 ekW @1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 44.90%

Cat G3520H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3520H Combined Heat and Power (CHP) Solution

Continuous Rating: 2480 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.40%

Cat G3516H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3516H Combined Heat and Power (CHP) Solution

Continuous Rating: 1982 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.90%

Cat G3512H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3512H Combined Heat and Power (CHP) Solution

Continuous Rating: 1490 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.50%

DG500 (3-Phase)
Gas Generator Sets

DG500 (3-Phase)

Frequency: 60 Hz
Natural Gas Rating: 500 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG100 (60 Hz)
Gas Generator Sets

DG100 (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 100 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency Application

DG125 (Single-phase and 3 phase) (60 Hz)
Gas Generator Sets

DG125 (Single-phase and 3 phase) (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 125 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application