G3512 750kW Gas Generator Set

Gas Generator Sets

Details

Gas Standby Rating
750 ekW @ 0.8pf

Fuel Type
Natural Gas, Hydrogen Blend (up to 5%)

Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Stationary Genset

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

525-750 kW Natural Gas Generator

Caterpillar is leading the power generation marketplace with Fast Response generator sets engineered to deliver unmatched performance, reliability, and cost-effectiveness.

Benefits

Certification

Leading edge EPA Certification For Non-Emergency, UL2200, UL1446, and more

Seconds

Complies with industry leading specifications such as NFPA 110 Level 1 Type 10

Block Load

Able to pick up the loads for the entire site in the event of an emergency.

Features at a Glance

Cat G3512 Gas Engine
  • Robust high speed block design provides prolonged life and lower owning operationg costs
  • Designed for maximum performance on low pressure pipeline natural gas and hydrogen blends
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
SR5 Generator
  • Designed to match performance and output characteristics of Caterpillar gas engines
  • Industry leading mechanical and electrical design
  • High efficiency
Cat ECS 100 Control Panel

Cat ECS 100 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 43°C (110°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Emissions
  • EPA Certified for use in Emergency and Non-Emergency applications
  • Additional a NOx selectable genset is available to meets most worldwide emissions requirements down to 0.5 g/bhp-hr NOx level without aftertreatment
Proven System
  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available
Full Range of Attachments
  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Gas Standby Rating
750 ekW @ 0.8pf

Fuel Type
Natural Gas, Hydrogen Blend (up to 5%)

Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Stationary Genset

RPM
1800 rpm

Frequency
60 Hz

Displacement
3173 in³

Engine Specifications

Engine Model
G3512

Displacement
3173 in³

Aspiration
TA

Bore
6.7 in

Stroke
7.5 in

Governor Type
ADEM A4

Generator Set Dimensions

Length
205.7 in

Width
90 in

Height
99.4 in

Weight
27500 lb

Equipment

Standard Equipment

Air Inlet

  • Dual air cleaners, 1 per side, with service indicator
  • Two-element single-stage air cleaner with enclosure and service indicator

Control Panel

  • Cat ECS 100

Cooling

  • Engine driven pumps for jacket water and separate circuit aftercooler
  • Jacket water and SCAC engine-driven pumps
  • Jacket water and SCAC thermostats
  • LH or RG connections when radiator is not selected
  • Package mounted radiator

Fuel

  • NOx sensor based air-fuel-ratio control
  • 0.5 to 5 psi engine fuel inlet pressure
  • Pipeline Natural Gas: 800-1000 BTU/scf and 70-100 Methane Number
  • Gas Train: NFPA37 and CSA B149.3

Exhaust

  • Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
  • Dry exhaust manifolds, insulated and shielded
  • Cat-flanged face outlet on turbocharger

Fuel System

  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
  • Throttle plate, 24V DC actuator, controlled by GECM
  • Engine-installed electronic control valve
  • Gas pressure regulator
  • 24V DC energized-to-run (ETR) gas shutoff valve

General

  • Crankshaft vibration damper and guard
  • Operation and maintenance manuals
  • Parts book
  • Paint- Caterpillar Yellow except rails and radiators gloss black 
  • RH Service

Lubrication

  • Gear type lube oil pump
  • Cartridge style oil filter

Generator

  • Anti-condensation space heater
  • Winding temperature detectors
  • NEMA Class H insulation
  • SR5
  • Permanent Magnet Excitiation
  • Caterpillar's Digital Voltage Regulator (CDVR) including reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, and a min/max exciter

Governing System

  • ADEM A4

Ignition System

  • Individual Cylinder Detonation Sensitive Timing (DST) 
  • Electronic Ignition System (controlled by ADEM A4) 

Governing

  • ADEM A4 speed governor with 4 to 20ma (0V to 5V) speed input

Starting/Charging

  • 24V DC starting motors
  • Batteries with rack and cables
  • Electric Starter
Optional Equipment

Air Inlet

  • Mounting brackets and piping
  • Air cleaner with precleaner

Circuit Breakers

  • S LSI, G LSIG, P LSIG-P, 4th Digit Type
  • Right, left, rear mounted
  • 1200A, 3 Pole, UL-100% Rated P-Frame Circuit Breakers
  • 1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers
  • 2000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers
  • 100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating
  • 3-pole (IEC 947-2 rated)
  • Frame mounting

Control Panel

  • Remote annunciator
  • Local alarm module
  • Local PC monitoring
  • Engine failure relay
  • Remote PC monitoring

Cooling

  • Coolant level drain line with valves, fan with guard
  • Remote radiator for JW and SCAC circuits, level switch included but not wired
  • Inlet/Outlet connections

Exhaust

  • 305 mm (12in.) elbow
  • 18, 25 dBA Attenuation
  • Flexible fittings
  • 305 mm (12 in.) muffler
  • 305mm (12 in) spark arresting muffler
  • 305 mm (12 in.) flange

Fuel System

  • 3, 0-100 kPag, 4-20mA gas train pressure sensors

General

  • Special paint order
  • US AID emblem
  • Tool set
  • Digital diagnostic tool

Generator

  • Cable access box
  • Generator air filter
  • European bus bars
  • Low voltage extension box
  • Bearing temperature detectors

Starting/Charging

  • 20A, 24VDC battery charger
  • Battery with cables and rack
  • Jacket water heater
  • 45A, 24V charging alternator (requires engine driven pumps)

Grid Code Compliance

  • 60 Hz: USA

Similar New Power Solutions

G3520H Gas Generator
Gas Generator Sets

G3520H Gas Generator

Continuous Rating: 2519 / 2500 ekW @ 1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 45.30%

G3512 1000kW Gas Generator Set
Gas Generator Sets

G3512 1000kW Gas Generator Set

Gas Standby Rating: 1000 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

Gas Generator G3512H
Gas Generator Sets

Gas Generator G3512H

Continuous Rating: 1515 ekW / 1505 ekW @1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 44.90%

Cat G3520H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3520H Combined Heat and Power (CHP) Solution

Continuous Rating: 2480 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.40%

Cat G3516H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3516H Combined Heat and Power (CHP) Solution

Continuous Rating: 1982 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.90%

Cat G3512H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3512H Combined Heat and Power (CHP) Solution

Continuous Rating: 1490 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.50%

DG500 (3-Phase)
Gas Generator Sets

DG500 (3-Phase)

Frequency: 60 Hz
Natural Gas Rating: 500 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG100 (60 Hz)
Gas Generator Sets

DG100 (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 100 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency Application

DG125 (Single-phase and 3 phase) (60 Hz)
Gas Generator Sets

DG125 (Single-phase and 3 phase) (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 125 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG150 (3 phase) (60 Hz)
Gas Generator Sets

DG150 (3 phase) (60 Hz)

Frequency: 60 Hz
Natural Gas Rating: 150 ekW