Maximum Rating
80 ekW

Minimum Rating
80 ekW

Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

80 ekW Diesel Generator Set

Producing reliable power of 80 ekW at 60 Hz, our D80 GC diesel generator sets are designed to meet ISO 8528-5 transient response requirements. All D80 GC generator sets meet EPA Stationary Emergency (Tier 3) emissions standards.

Benefits

Installed Space

Requires less space for installation; leaves more room for your on-going operations

Fulfillment within 24 hours

World's best product support network ensures spare parts are readily available for maintenance and service needs

Hours

Ensures you can count on emergency power when it is needed

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Maximum Rating
80 ekW

Minimum Rating
80 ekW

Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3

Voltage
208 to 600 Volts

Frequency
60 Hz

Speed
1800 rpm

Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel

Bore
4.1 in

Stroke
5 in

Displacement
269 in³

Compression Ratio
16.7:1

Aspiration
Turbocharged

Fuel System
Common Rail

Governor Type
Mechanical, ADEM™A4

Generator Set Dimensions

Length - Maximum
82.6 in

Width - Maximum
43.3 in

Height - Maximum
52.9 in

Dry Weight - Genset (maximum)
950 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element
  • Air cleaner

Cooling System

  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Coolant drain line with valve

Control Panel

  • GCCP 1.2 Control panel

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

  • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank

Generator

  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Voltage regulator (single phase sensing)
  • IP23 Protection
  • Segregated low voltage (AC/DC) wiring panel
  • 12 Leads
  • Tower panel, IP22, bottom cable entry

Governing System

  • Mechanical and electrical governing system - model dependent

Lube System

  • Lubricating oil
  • Oil drain line with valve

Mounting System

  • Includes lifting provision and drag points
  • Termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator

Starting/Charging System

  • Batteries
  • 24V battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment

Alternator System

  • 3 Phase sensing
  • Anti-condensation heater
  • R Frame auxilliary winding
  • Permanent magnet excitation (PMG)

Circuit breakers

  • Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A

Cooling System

  • Low coolant level shutdown
  • Coolant heater
  • Low coolant temperature alarm

Control Panel Options

  • Earth fault (2 wire only)
  • Overload shutdown via breaker
  • Earth leakage (2 wire only)
  • Volt free contacts
  • Panel mounted audible alarm
  • Battery charger
  • GCCP 1.2 Control panel
  • Control panel heater
  • Voltage adjust potentiometer
  • Emergency stop with key
  • Speed adjust potentiometer

Enclosures

  • Sound attenuated Level 2 enclosure

Fuel System

  • High fuel level alarm
  • Open set narrow tankbase
  • Low fuel level alarm
  • Bunded fuel tank
  • Low fuel level shutdown
  • Compact skidbase for open set
  • Skidbase for CALG enclosure sets

Global Certifications

  • Certification for CIS

Mounting Options

  • Battery removal
  • Industrial silencer
  • Electronic governor
  • External single point lift - enclosure
  • Silencer installation kit

Special Packing/Inspectons for Shipment

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

General - Accessories / Miscellaneous

  • Stone guards/rad trans flange
  • Packing case - canopied set
  • Packing case - compact set

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Maximum Rating: 9.5 kVA
Minimum Rating: 6.8 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Maximum Rating: 13.5 kVA
Minimum Rating: 10.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Maximum Rating: 65.0 kVA
Minimum Rating: 24.0 kVA
Emissions/Fuel Strategy: EU Stage II R96/EUIIIa

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Maximum Rating: 22.0 kVA
Minimum Rating: 13.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Maximum Rating: 110 kVA
Minimum Rating: 50 kVA
Emissions/Fuel Strategy: EU Stage II & R96/EUIIIa

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Maximum Rating: 220 kVA
Minimum Rating: 135 kVA
Emissions/Fuel Strategy: Non Regulated, EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption