D40 GC Generator Set

Diesel Generator Sets

Details

Maximum Rating
40 ekW

Minimum Rating
40 ekW

Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3, SCAQMD Compliant

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

40 kW Diesel Generator Set

Producing reliable power of 40 ekW at 60 Hz, our D40 GC diesel generator sets designed to ISO 8528-5 transient response requirements. All D40 GC generator sets meet EPA Stationary Emergency (Tier 3) emissions standards.

Benefits

Installed Space

Requires less space for installation; leaves more room for your on-going operations

Hours

Ensures you can count on emergency power when it is needed

Fulfillment within 24 hours

World's best product support network ensures spare parts are readily available for maintenance and service needs

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Maximum Rating
40 ekW

Minimum Rating
40 ekW

Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3, SCAQMD Compliant

Voltage
208 to 600 Volts

Frequency
60 Hz

Speed
1800 rpm

Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel

Bore
4.1 in

Stroke
5 in

Displacement
269 in

Compression Ratio
18.2:1

Aspiration
Turbocharged

Fuel System
Common Rail

Governor Type
Mechanical, ADEM™A4

Generator Set Dimensions

Length - Maximum
77.2 in

Width - Maximum
43.3 in

Height - Maximum
48 in

Dry Weight - Genset (maximum)
1847 lb

Equipment

Standard Equipment

Certificates

  • IBC seismic and wind Certifications

Air Inlet System

  • Air cleaner
  • Cartridge type air filter

Circuit breakers

  • Breakers (100% UL rated)
  • Second circuit breaker box
  • 3-Pole 100% rated
  • Power terminal strip

Charging System

  • NFPA battery charger UL10A 120VAC

Control Panel

  • GCCP 1.2 Control panel

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

  • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank

Control Panels

  • NFPA110 bundle includes:
  • WSS1 Low coolant level shut down
  • WCA1 Low coolant temperature alarm
  • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
  • PBC10NU NFPA battery charger
  • Oil temperature gauge and sender
  • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
  • PAA1 Panel mounted audible alarm
  • Remote E-stop button
  • Volt free contacts genset run and common alarm
  • Discrete I/O module
  • Audible alarm
  • Ground fault relay
  • Remote annunciator module
  • Overload shutdown via breaker
  • Low coolant level shutdown
  • Fuel level reading
  • Protective devices:
  • Low coolant temperature alarm

Cooling System

  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Radiator stone guard

Generator

  • 12 Leads

Governing System

  • Mechanical and electrical governing system - model dependent

Lube System

  • Lubricating oil
  • Oil drain line with valve

General

  • Engine and alternator pre-paint, Caterpillar yellow

Starting/Charging System

  • Batteries
  • 24V battery with rack and cables
Optional Equipment

Certificates

  • IBC seismic and wind Certifications

Air Inlet System

  • Cartridge type air filter

Alternator System

  • R Frame auxilliary winding

Charging System

  • NFPA battery charger UL10A 120VAC

Circuit breakers

  • Power terminal strip
  • Second circuit breaker box
  • Breakers (100% UL rated)
  • 3-Pole 100% rated

Control Panels

  • Volt free contacts genset run and common alarm
  • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
  • Discrete I/O module
  • Audible alarm
  • Ground fault relay
  • Remote annunciator module
  • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
  • Oil temperature gauge and sender
  • Remote E-stop button

Enclosures

  • Panel viewing window
  • Sound attenuated enclosure, Level 2
  • External emergency stop

Heating Elements

  • Anti-condensation heater
  • Coolant heater
  • Lube oil sump heater
  • Wiring for canopy space heater
  • Jacket water heater
  • Battery heater

Cooling System

  • Radiator transition flange

Fuel System

  • Emergency vent pipe
  • Tank riser
  • 209 and 394 gallon sub-base fuel tanks
  • 5 Gallon fill containment

Mounting System

  • Seismic vibration isolators

Tests

  • PGS Test report @ 1.0 power factor
  • 4 Hour factory test
  • PGS Test report @ 0.8 power factor
  • Generator test report

Exhaust System

  • 10, 25 and 35 dBA silencer systems
  • Overhead silencer mounting kit

Generators

  • Permanent magnet excitation (PMG) generator

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Maximum Rating: 9.5 kVA
Minimum Rating: 6.8 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Maximum Rating: 13.5 kVA
Minimum Rating: 10.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Maximum Rating: 65.0 kVA
Minimum Rating: 24.0 kVA
Emissions/Fuel Strategy: EU Stage II R96/EUIIIa

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Maximum Rating: 22.0 kVA
Minimum Rating: 13.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Maximum Rating: 110 kVA
Minimum Rating: 50 kVA
Emissions/Fuel Strategy: EU Stage II & R96/EUIIIa

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Maximum Rating: 220 kVA
Minimum Rating: 135 kVA
Emissions/Fuel Strategy: Non Regulated, EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption