C3.3 Generator Set

Diesel Generator Sets

Details

Maximum Rating
60.0 ekW

Minimum Rating
27.0 ekW

Emissions/Fuel Strategy
EU Stage II & R96/EUIIIa

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

27 - 60 ekW Diesel Generator Set

Producing reliable power from 27.0 to 60.0 ekW at 60 Hz, our C3.3 diesel generator sets designed to ISO 8528-5 transient response requirements. All C3.3 generator sets are R96/EUIIIa equivalent emissions compliant.

Benefits

& Testing environments

Lower Fuel Consumption

Longer run times between fuel fills; reduced operating costs

Hours

Ensures you can count on emergency power when it is needed

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
R-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
  • Image may not be a representative of actual product
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Maximum Rating
60.0 ekW

Minimum Rating
27.0 ekW

Emissions/Fuel Strategy
EU Stage II & R96/EUIIIa

Voltage
110 to 480 Volts

Frequency
60 Hz

Speed
1800 rpm

Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
Cat® C3.3

Bore
4.1 in

Stroke
5 in

Displacement
201.4 in³

Compression Ratio
17.25:1, 19.25:1

Aspiration
Turbocharged

Fuel System
Direct Injection

Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
43.9 in

Width - Maximum
38.2 in

Height - Maximum
53.6 in

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element

Control Panel

  • GCCP 1.3

Cooling System

  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive

Exhaust System

  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose

Fuel System

  • Standard open set fuel tank/base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Generators and Generator Attachments

  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • IP23 Protection
  • Tower panel, IP22, bottom cable entry
  • 12 Leads
  • Voltage regulator (single phase sensing)
  • Segregated low voltage (AC/DC) wiring panel

Governing System

  • Mechanical governing system - model dependant
  • Mechanical and electrical governing system - model dependant

Lube System

  • Lubricating oil
  • Oil drain line with valve

Mounting System

  • includes lifting provisions and termination points for coolant
  • Includes lifting provision and drag points
  • Termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator

Starting / Charging System

  • 12V Battery with rack & cables

General

  • Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment

Alternator System

  • LC Frame alternator
  • Anti-condensation heater
  • Permanent magnet excitation (PMG)
  • LC Frame alternator with coastal protection
  • R Frame auxilliary winding

Alternator

  • Alternator removal options

Circuit breakers

  • 4 Pole Circuit breaker to 250A
  • Padlockable breaker device

Control Panels

  • GCCP 1.3

Control Panel Options

  • Overload shutdown via breaker
  • Volt free contacts
  • Earth leakage (2 wire only)
  • Speed adjust potentiometer
  • Voltage adjust potentiometer
  • Battery charger
  • Control panel heater
  • Earth fault (2 wire only)
  • Panel mounted audible alarm
  • Emergency stop with key

Cooling System

  • Coolant heater
  • Low coolant level shutdown
  • Low coolant temperature alarm

Certifications

  • European upgrade to STD set for "CE"
  • Global certification for CIS

Enclosures

  • CEE for sockets for enclosure
  • Socket blanking plate
  • Sound attenuated level 1 enclosure (GALV)
  • Sound attenuated level 2 enclosure CE
  • Rental pack (CAE only)

Fuel System

  • Skidbase for CALG enclosure sets
  • Low fuel level shutdown
  • High fuel level alarm
  • Compact skidbase for open sets
  • Low fuel level alarm
  • Bunded fuel tank
  • Open set narrow tankbase

Mounting Options

  • Silencer installation kit
  • Battery removal
  • Electronic governor
  • Residential silencer
  • External single point lift - enclosure

Special Packing Inspections

  • PGS Test report @ 0.8 power factor
  • PGS Test report @ 1.0 power factor

General

  • Stone guards/rad trans flange
  • Packing case - compact set
  • Packing case - canopied set

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Maximum Rating: 9.5 kVA
Minimum Rating: 6.8 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Maximum Rating: 13.5 kVA
Minimum Rating: 10.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Maximum Rating: 65.0 kVA
Minimum Rating: 24.0 kVA
Emissions/Fuel Strategy: EU Stage II R96/EUIIIa

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Maximum Rating: 22.0 kVA
Minimum Rating: 13.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Maximum Rating: 110 kVA
Minimum Rating: 50 kVA
Emissions/Fuel Strategy: EU Stage II & R96/EUIIIa

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Maximum Rating: 220 kVA
Minimum Rating: 135 kVA
Emissions/Fuel Strategy: Non Regulated, EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption