C1.1 Generator Set

Diesel Generator Sets

Details

Maximum Rating
8.8 ekW

Minimum Rating
8.0 ekW

Emissions/Fuel Strategy
R96/EUIIIa Equivalent

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

8.0 - 8.8 ekW Diesel Generator Set

Producing reliable power from 8.0 to 8.8 ekW at 60 Hz, our C1.1 diesel generator sets designed to ISO 8528-5 transient response requirements. All C1.1 generator sets are R96/EUIIIa equivalent emissions compliant.

Benefits

Continuous Run Time

Monitoring

Cat Connect option ensures your generator set is always ready to start and performing as expected

Environments

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
  • Image may not be a representative of actual product
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat® SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
        
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  •     
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Maximum Rating
8.8 ekW

Minimum Rating
8.0 ekW

Emissions/Fuel Strategy
R96/EUIIIa Equivalent

Voltage
110 to 480 Volts

Frequency
60 Hz

Speed
1800 rpm

Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C1.1, In-line 4, 4-cycle diesel

Bore
3 in

Stroke
3.2 in

Displacement
69 in

Compression Ratio
23.0:1

Aspiration
Naturally Aspirated

Fuel System
Indirect Injection

Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
55.1 in

Width - Maximum
24.4 in

Height - Maximum
39.2 in

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element

Control Panel

  • GCCP 1.3

Cooling System

  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive

Exhaust System

  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose

Fuel System

  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank/base supplied

Generators and Generator Attachments

  • 12 Leads
  • IP23 Protection
  • Segregated low voltage (AC/DC) wiring panel
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Voltage regulator (single phase sensing)
  • Tower panel, IP22, bottom cable entry

Governing System

  • Mechanical governing system

Lube System

  • Lubricating oil
  • Oil drain line with valve

Mounting System

  • Includes lifting provisions and termination points for coolant
  • Captive linear vibration isolators between base and engine-generator

Starting / Charging System

  • 12 Volt battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment

Alternator Options

  • Coastal insulation protection

Certificates

  • European upgrade to STD set for CE certificate
  • Global certification for CIS

Circuit breakers

  • Padlockable breaker device
  • 4 Pole Circuit breaker

Control Panel

  • Battery charger
  • Volt free contacts for common alarm
  • Volt free contacts for genset running
  • Emergency stop with key
  • GCCP 1.3

Cooling System

  • Coolant heater

Enclosures

  • Single point lift for enclosure
  • Sound attenuated enclosure (GALV)

Fuel System

  • Fuel transfer control
  • Base feet
  • 1000 hr extended service interval
  • Skidbase for enclosures
  • Skidbase for open sets
  • DEFRA bunded fuel tank
  • Low fuel level alarm

Mounting Options

  • Industrial silencer removal
  • Battery removal
  • Silencer installation kit

Special Test and Inspection

  • PGS Test report @ 1.0 power factor

General

  • Radiator stone guard
  • Packing case - canopied set
  • Packing case - compact set

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Maximum Rating: 9.5 kVA
Minimum Rating: 6.8 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Maximum Rating: 13.5 kVA
Minimum Rating: 10.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Maximum Rating: 65.0 kVA
Minimum Rating: 24.0 kVA
Emissions/Fuel Strategy: EU Stage II R96/EUIIIa

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Maximum Rating: 22.0 kVA
Minimum Rating: 13.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Maximum Rating: 110 kVA
Minimum Rating: 50 kVA
Emissions/Fuel Strategy: EU Stage II & R96/EUIIIa

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Maximum Rating: 220 kVA
Minimum Rating: 135 kVA
Emissions/Fuel Strategy: Non Regulated, EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption