MX150 Microprocessor Controller

ATS MX Contactor

Details

Rating Range
Switch Dependent

Transfer Type
Application Dependent

Switch Type
Application Dependent

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

The MX150 microprocessor is standard with the CTG product family. The MX150 microprocessor panel controls the operation and displays thes tatus of the transfer switch's position, timer sand available sources.
As an embedded digital controller, the MX series offers high reliability and ease of unattended operation across a range of applications.

Benefits

microprocessor

is standard with the CTG product family

offers high reliability and ease of unattended operation across a range of applications

Features at a Glance

Features and Benefits
  • Digital timer and adjustments with 1 second resolution
  • Long lasting LED indicators and an easy-to-view LCD display
  • Inputs optoisolated for high electrical immunity to transients and noise
  • Digital voltage and frequency adjustments with1% resolution
  • Voltage and frequency sensing includes:
    –Voltage imbalance detection between phases
    –Under frequency sensing on source 2
    –3 Phase under voltage sensing on source 1(S1)
    – Normal and single phase sensing onsource (S2)
    – Emergency
  • Modular pre-signal option easily integrated into the system (e.g. elevator pre-signal and motor load disconnect)
  • Universal Motor Disconnect (UMD) available for programming to pre-signal, post-signal or both
  • Line voltage transients are isolated from the control board using remote transformers
  • Simplified major components and modules for easy replacement
  • On-board diagnostics including voltage frequency, control and timing
  • Nonvolatile memory – battery backup not required during normal source outage
  • External communication available through LonWorks/ModBus network interface (RS232,RS 422, and RS 485 are also available)
  • Maintained and momentary test positions are available to the controller
  • Test mode allows manual bypass of all transfer timers when applicable
  • Automatic daylight savings adjustment available
User-Friendly Operation
  • LEDs for continuous monitoring of switch position, source availability, exercise time delay operation and diagnostics
  • Simplified adjustment for voltage, frequency and time delay settings
  • Close differential 3 phase under-voltage sensing of source 1, factory standard setting 90% pickup,80% dropout (adjustable); under-frequency sensing of the source 1 factory setting 95% pickup (adjustable)
  • Voltage and frequency sensing of source 2,factory standard setting 90% pickup voltage,95% pickup frequency (adjustable)
  • Test switch (fast test/load/no load) to simulate normal source failure – automatically bypassed should source 2 fail

Specifications

Full Specifications

Technical Summary

Rating Range
Switch Dependent

Transfer Type
Application Dependent

Switch Type
Application Dependent

Controller Specifications

Undervoltage Dropout for Source 1 and Source 2
75-98% of nominal

Undervoltage Restore for Source 1 and Source 2
85-100% of nominal

Underfrequency Dropout for Source 1 and Source 2
88-98% of nominal

Underfrequency Restore for Source 1 and Source 2
90-100% of nominal

Delay for Engine Cool Down (U)
0-10 seconds

Delay Transfer to Nonpreferred Source (W)
0-5 minutes

Delay NeutralTransition Time Delays (DT,DW)
0-10 minutes

Storage Temperature
(-30˚C - 75˚C ), -22˚F - 167˚F

Operating Temperature Ambient
40 - 400 amp molded shell (-20˚C to 65˚C) , -4˚F to 149˚F<br>40 - 4000 amp all others (-20˚C to 60˚C), -4˚F to 149˚F

Similar New Power Solutions

MX250 Microprocessor Controller
ATS MX Contactor

MX250 Microprocessor Controller

Rating Range: Switch Dependent
Transfer Type: Application Dependent
Switch Type: Application Dependent

MX350 Controller
ATS MX Contactor

MX350 Controller

Voltage Unbalance on Dropout for Source 1 and Source 2: 5 to 20% of nominal
Delay NeutralTransition Time Delays (DT,DW): 0-10 minutes
Control Power: 120 VAC

CTS Series Automatic Transfer Switch
ATS MX Contactor

CTS Series Automatic Transfer Switch

Rating Range: 40 to 4000A
Transfer Type: Open transition
Switch Type: Contactor Based

CTG Series Automatic Transfer Switch
ATS MX Contactor

CTG Series Automatic Transfer Switch

Transfer Type: Open transition
Rating Range: 40-3000A
Switch Type: Contactor based

CTX Series Automatic Transfer Switch
ATS MX Contactor

CTX Series Automatic Transfer Switch

Rating Range: 40-400A
Transfer Type: Open transition
Switch Type: Contactor Based

CTE Series Automatic Transfer Switch
ATS MX Contactor

CTE Series Automatic Transfer Switch

Rating Range: 40-4000A
Transfer Type: Open / Closed / 4 position switch
Switch Type: Contactor Based

CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch
ATS MX Contactor

CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch

Switch Type: Contactor Based
Transfer Type: Open Transition with Service Entrance
Rating Range: 40-3000A

CTSM and CTGM Series Manual Transfer Switches
ATS MX Contactor

CTSM and CTGM Series Manual Transfer Switches

Rating Range: 40-4000A
Transfer Type: Open / Manual