CTX Series Automatic Transfer Switch

ATS MX Contactor

Details

Rating Range
40-400A

Transfer Type
Open transition

Switch Type
Contactor Based

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

Cat® CTX Series switches are built for residential and light commercial applications requiring the dependability and ease of operation found in a power contactor switch.
Voltage sensing and system control is performed via a state-of-the-art microcontroller located on the cabinet door.

Benefits

Control Panel

adds a user interface and functionality

for power availability, switch position, and load energized

Pushbuttons for test, exercise set, timer bypass, and program cancel

status annunciation of in-phase transfer and times operation Selectable 7, 14, 21 or 28 day (factory set 28 days) generator exerciser timer

Diagnostic LED indications in logical one-line configuration

Features at a Glance

MX Control Panel
    CTX switches are equipped with the MX-60 control panel as standard.
    This microprocessor control includes:
  • Undervoltage sensing (90% pickup/80% dropout of the utility source
    • Voltage and frequency sensing of the generator source (90% voltage/95% frequency pickup)
    • Time Delay Engine Start – 5 seconds (P)
    • Time Delay Engine Warmup – Transfer to Generator – 20 seconds (W)
    • Time Delay Utility Stabilization/Retransfer to Utility – 5 minutes (T)
    • Time Delay Engine Cool Down – 5 minutes (U)

    All time delays are fixed.

Specifications

Full Specifications

Technical Summary

Rating Range
40-400A

Transfer Type
Open transition

Switch Type
Contactor Based

Equipment

Standard Equipment

The unit is available in open type, NEMA 1 or NEMA 3R enclosures. The MX-60 control panel adds a user interface and functionality, including:

  • Pushbuttons for test, exercise set, timer bypass and program cancel
  • Special status annunciation of in-phase transfer and times operation
  • Diagnostic LED indications in logical one-line configuration
  • Selectable 7, 14, 21 or 28 day (factory set 28 days) generator exerciser timer
  • Indicating LEDs for power availability, switch position and load energized

Additional options include:

  • A3/A4 Auxiliary contacts (1 each) closed in utility and generator positions
  • Special timer settings

Similar New Power Solutions

MX150 Microprocessor Controller
ATS MX Contactor

MX150 Microprocessor Controller

Rating Range: Switch Dependent
Transfer Type: Application Dependent
Switch Type: Application Dependent

MX250 Microprocessor Controller
ATS MX Contactor

MX250 Microprocessor Controller

Rating Range: Switch Dependent
Transfer Type: Application Dependent
Switch Type: Application Dependent

MX350 Controller
ATS MX Contactor

MX350 Controller

Voltage Unbalance on Dropout for Source 1 and Source 2: 5 to 20% of nominal
Delay NeutralTransition Time Delays (DT,DW): 0-10 minutes
Control Power: 120 VAC

CTS Series Automatic Transfer Switch
ATS MX Contactor

CTS Series Automatic Transfer Switch

Rating Range: 40 to 4000A
Transfer Type: Open transition
Switch Type: Contactor Based

CTG Series Automatic Transfer Switch
ATS MX Contactor

CTG Series Automatic Transfer Switch

Transfer Type: Open transition
Rating Range: 40-3000A
Switch Type: Contactor based

CTE Series Automatic Transfer Switch
ATS MX Contactor

CTE Series Automatic Transfer Switch

Rating Range: 40-4000A
Transfer Type: Open / Closed / 4 position switch
Switch Type: Contactor Based

CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch
ATS MX Contactor

CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch

Switch Type: Contactor Based
Transfer Type: Open Transition with Service Entrance
Rating Range: 40-3000A

CTSM and CTGM Series Manual Transfer Switches
ATS MX Contactor

CTSM and CTGM Series Manual Transfer Switches

Rating Range: 40-4000A
Transfer Type: Open / Manual
Switch Type: Contactor Based