CTGSE & CTGDSE Series Service Rated Entrance Rated Automatic Transfer Switch

ATS MX Contactor

Details

Switch Type
Contactor Based

Transfer Type
Open Transition with Service Entrance

Rating Range
40-3000A

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

Cat® CTGSE series automatic transfer switches (ATS)integrates the utility circuit breaker, optional transient voltage surge suppression and power monitoring into one package. The CTGDSE series provides delayed transition operation of the ATS. The MX150 controller displays the status of the transfer switch's position, timers and available sources. A communications network interface is available as an option.

Benefits

Controller

with non-volatile memory-clock battery backup not required for standard switch operation

standard with NEMA 3R as an option

Disconnect link on Neutral and Ground

Switch

(fast test, load, no load) to simulate normal source failure automatically bypassed should Source 2 fail

Features at a Glance

Performance Features

Timer and voltage/frequency settings adjustable without disconnection from the power source

Processor and digital circuitry isolated from line voltage

Inputs are opto-isolated for high electrical immunity to transients and noise

Built-in diagnostics with LCD display and LED/LCD indicators for ease of viewing and long life

Specifications

Full Specifications

Technical Summary

Switch Type
Contactor Based

Transfer Type
Open Transition with Service Entrance

Rating Range
40-3000A

Equipment

Standard Equipment

Electrical Ratings

  • UL 891,UL 1008,SA 22.2,IEC 947-6-1
  • ESD immunity test per EN61000-4-2 (Level 4)
  • Electrical fast transient/burst immunity test per EN61000-4-4
  • NFPA70,99,101 & 110
  • Ringing wave immunity per IEEE 472 (ANSI C37.90A)
  • Ratings 40 to 3000 amperes
  • Voltage Dips and interruption immunity EN61000-4-11
Optional Equipment

Optional Attachments

  • Additional options include integrated battery charger, shunt trip selector, power monitor and integrated TVSS
  • Optional integrated load center for multiple loadside connections available up to 240 volts

Similar New Power Solutions

MX150 Microprocessor Controller
ATS MX Contactor

MX150 Microprocessor Controller

Rating Range: Switch Dependent
Transfer Type: Application Dependent
Switch Type: Application Dependent

MX250 Microprocessor Controller
ATS MX Contactor

MX250 Microprocessor Controller

Rating Range: Switch Dependent
Transfer Type: Application Dependent
Switch Type: Application Dependent

MX350 Controller
ATS MX Contactor

MX350 Controller

Voltage Unbalance on Dropout for Source 1 and Source 2: 5 to 20% of nominal
Delay NeutralTransition Time Delays (DT,DW): 0-10 minutes
Control Power: 120 VAC

CTS Series Automatic Transfer Switch
ATS MX Contactor

CTS Series Automatic Transfer Switch

Rating Range: 40 to 4000A
Transfer Type: Open transition
Switch Type: Contactor Based

CTG Series Automatic Transfer Switch
ATS MX Contactor

CTG Series Automatic Transfer Switch

Transfer Type: Open transition
Rating Range: 40-3000A
Switch Type: Contactor based

CTX Series Automatic Transfer Switch
ATS MX Contactor

CTX Series Automatic Transfer Switch

Rating Range: 40-400A
Transfer Type: Open transition
Switch Type: Contactor Based

CTE Series Automatic Transfer Switch
ATS MX Contactor

CTE Series Automatic Transfer Switch

Rating Range: 40-4000A
Transfer Type: Open / Closed / 4 position switch
Switch Type: Contactor Based

CTSM and CTGM Series Manual Transfer Switches
ATS MX Contactor

CTSM and CTGM Series Manual Transfer Switches

Rating Range: 40-4000A
Transfer Type: Open / Manual
Switch Type: Contactor Based