ATC Service Entrance Rated MCCB & Power Breaker Based ATS

ATS ATC Breaker / Contactor

Details

Rating Range
30-5000A

Transfer Type
Open / Closed / Delayed

Switch Type
Molded Case and Power Breaker

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

Cat® Service Entrance Rated (SER) automatic transfer switches (ATS) are designed to provide standby power emergency power to entire installation loads to protect against utility power interruption; yet allow the ATS to be as close as possible to the point of service entrance. By safely and in code compliance, integrating the necessary overcurrent protection and service disconnecting means into the automatic transfer switch, a single installation can be made at the service entrance. This design eliminates the need for a separate upstream fault protection and respective interconnections, which in turn reduces installation space, time, and cost. Breaker-based Service Entrance Rated transfer switches are available from 30A to 5000A.

Benefits

on MCCB & Power Breaker ATS products Keyed service entrance switch

Draw-out type breakers (available on Power Breaker ratings) UL 891 for 4000-5000A

controls relays and industrial grade relays

Lugs are 90� rated and all control wire is #16 AWG, type XLPE with a 125� temperature rating

powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges.

The hinges have removable hinge pins to facilitate door removal and are supplied with pad-lockable latches.

Features at a Glance

Product Features
  • ATC-100 on Residential & Light Commercial MCCB based, ATC-300+ or ATC-800 on MCCB & Power Breaker ATS products
  • UL 1008 service entrance listed (up to 3200A)
  • Service disconnect (both off) capability
  • Integral over current protection
  • Lockout when in disconnected position (only)
  • Service entrance labeled
  • Integrated Design
  • Disconnecting neutral assembly
  • Ground fault protection capability (all ratings)
    (Required by code on rating 480V, and 1000A or higher)
  • Keyed service entrance switch
  • Draw-out type breakers (available on Power Breaker ratings)
  • UL 891 for 4000-5000A
  • Loads protected against extended power loss
  • Quick restoration of the circuit after a trip (versus a fused circuit that requires fuse availability)
  • Trip on a fault prohibits transfer to the emergency source
  • Fused circuit allows switch testing by simulating an actual power failure
  • Lockable disconnect position permits safe downstream maintenance

Specifications

Full Specifications

Technical Summary

Rating Range
30-5000A

Transfer Type
Open / Closed / Delayed

Switch Type
Molded Case and Power Breaker

Ratings

MCCB
30-1000A 2, 3, or 4 Pole

Fixed Mount Power Breaker
200-3200A 2, 3, 4-Pole

Drawout Power Breaker
200-5000A 2, 3, or 4-Pole

System Voltage Application
120-600 Vac 50/60 Hz

Withstand
(Power Breaker) Up to 100 kAIC at 600V 3 cycles

Applicable Testing
<CSA C22.2 No. 178 certified</br><br> UL 1008 listed up to 3200A</br><br>4000A, and 5000A UL 891 listed</br>

Equipment

Standard Equipment

Controls and Wiring

  • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.

Enclosure

  • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.
Optional Equipment

Available Options

  • 4-position test switch
  • Remote communications
  • Surge suppression
  • Selectable automatic or non-automatic operation
  • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)
  • Communications for the ATC-300+ controller via RS-232 or Modbus through an integrated RS-485 port
  • Field selectable, multi ratio, control voltage transformer 50/60 Hz
  • Load sequencing contacts
  • Multi-meter options available
  • Open, closed or delayed transition
  • Space heaters
  • Integral overcurrent protection

Optional Delayed Transition includes:

  • Pre-transfer signal with 1 N.O. and 1 N.C. contacts
  • Time delay neutral

Similar New Power Solutions

ATC-300+ CONTROLLER
ATS ATC Breaker / Contactor

ATC-300+ CONTROLLER

Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type: Switch application dependent
Switch Type: Switch application dependent

ATC-800 CONTROLLER
ATS ATC Breaker / Contactor

ATC-800 CONTROLLER

Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type: Switch application dependent
Switch Type: Switch application dependent

ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch

Rating Range: 200-5000A
Transfer Type: Bypass isolation, Closed transition
Switch Type: Power Breaker

ATC Contactor-Based Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Contactor-Based Automatic Transfer Switch

Rating Range: 40-1600A
Transfer Type: Open / Closed Transition
Switch Type: Contactor Based

ATC Contactor Based Bypass Isolation Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Contactor Based Bypass Isolation Automatic Transfer Switch

Rating Range: 100 to 1200A
Transfer Type: Bypass Isolation
Switch Type: Contactor Based

ATC Power Breaker & Case Switch Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Power Breaker & Case Switch Automatic Transfer Switch

Rating Range: 200 to 5000A
Transfer Type: Open Transition
Switch Type: Power Breaker

ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch

Rating Range: 30-1000A
Transfer Type: Open transition
Switch Type: Molded Case