ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch

ATS ATC Breaker / Contactor

Details

Rating Range
200-5000A

Transfer Type
Bypass isolation, Closed transition

Switch Type
Power Breaker

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. A Bypass Isolation Automatic Transfer Switch (ATS) provides fully functioning transfer in applications where emergency power to critical loads must be maintained at all times with no interruption. This type of design allows for inspection, maintenance or replacement of the power switching mechanisms with no interruption in electrical service. Breaker based Bypass isolation ATS are available from 200A to 5,000A.

Benefits

microprocessor-based controller and Power Breaker

Full 30-cycle short time withstand capability 30-cycle, 85 kA short-time rating on power circuit breaker

controls relays and industrial grade relays

Lugs are 90� rated and all control wire is #16 AWG, type XLPE with a 125� temperature rating.

Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges.

The hinges have removable hinge pins to facilitate door removal and are supplied with pad-lockable latches.

Features at a Glance

Product Features
  • ATC-800 microprocessor-based controller
  • True RMS voltage and frequency sensing
  • Full 30-cycle short time withstand capability
  • 30-cycle, 85 kA short-time rating on power circuit breaker
  • Multiple field programmable time delays
  • Switch position indication
  • Source availability indication
  • Source 1 and 2 auxiliary contacts
  • Programmable plant exerciser
  • System test pushbutton
  • Load shed from emergency
  • Mimic diagram
  • Safe manual operation under full load with permanently affixed operating handle
  • Drawout capabilities on both ATS, bypass portions and power switching devices completely interchangeable between ATS and bypass units

Specifications

Full Specifications

Technical Summary

Rating Range
200-5000A

Transfer Type
Bypass isolation, Closed transition

Switch Type
Power Breaker

Ratings

Control Power
200-5000A, 2-, 3-, 4-pole<br>100% rated Short

System Voltage Application
120-600 Vac 50/60 Hz

Time Withstand
85,000 for 30 cycles

Withstand
100 kAIC at 600V, 3 cycles

Applicable Testing
CSA C22.2 No. 178 certified<br> UL 1008 listed up to 3200A<br>4000A, and 5000A UL 891 listed

Equipment

Standard Equipment

Controls and Wiring

  • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.

Enclosure

  • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.
Optional Equipment

Available Options

  • Surge suppression
  • Field selectable, multi ratio, control voltage transformer 50/60 Hz
  • Integrated service entrance
  • Space heaters
  • Remote communications
  • Multi-meter options available
  • 2- or 4-position test switch
  • Selectable automatic or non-automatic operation
  • Open or closed transition
  • Load sequencing contacts
  • Integral overcurrent protection
  • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)

Optional Delayed Transition includes:

  • Pre-transfer signal with 1 N.O. and 1 N.C. contacts
  • Time delay neutral
  • In-phase transition

Similar New Power Solutions

ATC-300+ CONTROLLER
ATS ATC Breaker / Contactor

ATC-300+ CONTROLLER

Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type: Switch application dependent
Switch Type: Switch application dependent

ATC-800 CONTROLLER
ATS ATC Breaker / Contactor

ATC-800 CONTROLLER

Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type: Switch application dependent
Switch Type: Switch application dependent

ATC Service Entrance Rated MCCB & Power Breaker Based ATS
ATS ATC Breaker / Contactor

ATC Service Entrance Rated MCCB & Power Breaker Based ATS

Rating Range: 30-5000A
Transfer Type: Open / Closed / Delayed
Switch Type: Molded Case and Power Breaker

ATC Contactor-Based Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Contactor-Based Automatic Transfer Switch

Rating Range: 40-1600A
Transfer Type: Open / Closed Transition
Switch Type: Contactor Based

ATC Contactor Based Bypass Isolation Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Contactor Based Bypass Isolation Automatic Transfer Switch

Rating Range: 100 to 1200A
Transfer Type: Bypass Isolation
Switch Type: Contactor Based

ATC Power Breaker & Case Switch Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Power Breaker & Case Switch Automatic Transfer Switch

Rating Range: 200 to 5000A
Transfer Type: Open Transition
Switch Type: Power Breaker

ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch

Rating Range: 30-1000A
Transfer Type: Open transition
Switch Type: Molded Case