ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch

ATS ATC Breaker / Contactor

Details

Rating Range
30-1000A

Transfer Type
Open transition

Switch Type
Molded Case

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. The open transition breaker-based Automatic Transfer Switch (ATS) will provide fully functioning transfer in applications where a momentary loss of power is acceptable on retransfer from emergency to normal power supply. The Cat Open Transition MCCB & MCS types of ATS also permits periodic testing of the emergency source without interrupting power to the loads and are available from 30 to 1000 amperes.

Benefits

microprocessor-based controller

Durable powder-coated steel NEMA 1, NEMA 3R, NEMA 4 and NEMA 12

controls relays and industrial grade relays

Lugs are 90� rated and all control wire is #16 AWG, type XLPE with a 125� temperature rating

types of ATS

also permits periodic testing of the emergency source without interrupting power to the loads

Features at a Glance

Product Features
  • ATC-100, ATC-300+ or ATC-800 microprocessor-based controller
  • Mechanical (cable) and electrical interlocking to prevent paralleling of sources
  • Voltage and frequency sensing
  • Multiple field programmable time delays
  • Switch position indication
  • Source availability indication
  • Safe manual transfer under load
  • Source 1 and Source 2 auxiliary contacts
  • Programmable plant exerciser
  • System test pushbutton
  • Load Shed from emergency (ATC-800 only)
  • Mimic diagram
  • Mechanical (cable) and electrical interlocking to prevent paralleling of sources
  • Safe manual operation under full load with permanently affixed operating handle
  • Ambient temperature range: -40C to 40C (-40F to 104F)
  • Operating temperature range: -20C to 70C (-4F to 158F)
  • Operating humidity: up to 90%
  • Relative humidity (non-condensing)
  • Frequency sensing on Source 1 and 2
  • True RMS three phase voltage sensing on Source 1, Source 2 and load

Specifications

Full Specifications

Technical Summary

Rating Range
30-1000A

Transfer Type
Open transition

Switch Type
Molded Case

Ratings

Control Power
30-1000A 2, 3, or 4 Pole, 100% Rated

System Voltage Application
120 - 600 Vac, 50/60 Hz

Withstand
100,000 amps withstand/closing/ interrupting at480 Vac

Applicable Testing
CSA C22.2 No. 178 certified<br>IBC 2006, CBC 2007 and OSHPD

Equipment

Standard Equipment

Controls and Wiring

  • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.

Enclosure

  • Durable powder-coated steel NEMA 1, NEMA 3R and NEMA 12 are available with ATC-100 and ATC-300+ controllers. NEMA 4 is only available with the ATC-800 controller. The enclosures are Seismic Qualified (BOCA, CBC, IBC, UBC). The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.
Optional Equipment

Available Options

  • Suitable for service entrance
  • Load sequencing contacts
  • Selectable automatic or non-automatic operation
  • Controller availability: ATC-100, ATC-300+,and ATC-800
  • Field selectable, multi ratio, control voltage transformer 50/60 Hz
  • Surge suppression
  • Multi-meter options available
  • Integral overcurrent protection
  • Space heaters
  • Remote communications
  • Communications for the ATC-300+ Controller via RS-232 or Modbus through an integrated RS-485 port
  • 2- or 4-position test switch

Optional Delayed Transition includes:

  • Pre-transfer signal with 1 N.O. and 1 N.C. contacts
  • Time delay neutral

Similar New Power Solutions

ATC-300+ CONTROLLER
ATS ATC Breaker / Contactor

ATC-300+ CONTROLLER

Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type: Switch application dependent
Switch Type: Switch application dependent

ATC-800 CONTROLLER
ATS ATC Breaker / Contactor

ATC-800 CONTROLLER

Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type: Switch application dependent
Switch Type: Switch application dependent

ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch

Rating Range: 200-5000A
Transfer Type: Bypass isolation, Closed transition
Switch Type: Power Breaker

ATC Service Entrance Rated MCCB & Power Breaker Based ATS
ATS ATC Breaker / Contactor

ATC Service Entrance Rated MCCB & Power Breaker Based ATS

Rating Range: 30-5000A
Transfer Type: Open / Closed / Delayed
Switch Type: Molded Case and Power Breaker

ATC Contactor-Based Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Contactor-Based Automatic Transfer Switch

Rating Range: 40-1600A
Transfer Type: Open / Closed Transition
Switch Type: Contactor Based

ATC Contactor Based Bypass Isolation Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Contactor Based Bypass Isolation Automatic Transfer Switch

Rating Range: 100 to 1200A
Transfer Type: Bypass Isolation
Switch Type: Contactor Based

ATC Power Breaker & Case Switch Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Power Breaker & Case Switch Automatic Transfer Switch

Rating Range: 200 to 5000A
Transfer Type: Open Transition
Switch Type: Power Breaker