ATC Contactor-Based Automatic Transfer Switch

ATS ATC Breaker / Contactor

Details

Rating Range
40-1600A

Transfer Type
Open / Closed Transition

Switch Type
Contactor Based

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview


Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. The open and delayed transition contactor-based Automatic Transfer Switch (ATS) provides fully functioning transfer in Applications where a momentary loss of power is acceptable during transfer and retransfers between normal and emergency power supply.

The closed transition contactor-based ATS is designed to Meet application requirements where emergency back up power is required with no momentary loss of power by connecting both sources before the transfer occurs. Closed transition also permits periodic testing of the emergency power source without interrupting power to the loads.

Benefits

microprocessor-based controller

flexibility, reliability and value

in a compact package

transition

permits periodic testing of the emergency power source without interrupting power to the loads

Features at a Glance

Product Features
  • ATC-100, ATC-300+ or ATC-800 microprocessor-based controller
  • Voltage and frequency sensing
  • High withstand and closing ratings
  • Multiple field programmable set points
  • Status Display including switch position indication
  • Source availability indication
  • Source 1 and 2 auxiliary contacts
  • True RMS voltage and frequency sensing
  • Programmable plant exerciser
  • System test pushbutton
  • Mimic diagram
  • Double-throw, mechanically interlocked transfer mechanism
  • Switch position indication
  • Status display
  • Double-throw UL 1008 3-position contactors

Specifications

Full Specifications

Technical Summary

Rating Range
40-1600A

Transfer Type
Open / Closed Transition

Switch Type
Contactor Based

Ratings

Control Power
Wall Mount 40-600A 2 or 3 Pole<br>Floor Standing 600A 4 Pole & 800-1200A 2, 3, or 4 Pole

Two-Position Contactors
Two-position contactors 40-400A

Three-Position Contactors
Three-position contactors 40-1200A

System Voltage Application
Up to 600 Vac, 50/60 Hz

Applicable Testing
UL 1008 listed, CSA C22.2 No. 178 certified, IBC 2006, CBC 2007 and OSHPD

Equipment

Standard Equipment

Contact Composition

  • Caterpillar utilizes silver composition contacts designed to meet the stringent requirements of UL 1008. All contactors are designed so that the contacts can be visually inspected without major disassembly and are protected by arcing contacts.

Controls and Wiring

  • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.

Enclosure

  • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.
Optional Equipment

Available Options

  • 2- or 4-position test switch
  • Controller availability: ATC-100, ATC-300+,and ATC-800
  • Delayed transition or closed transition
  • Multi-meter options available
  • Surge suppression
  • Space heaters
  • Field selectable, multi ratio, control voltage transformer 50/60 Hz
  • Selectable automatic or non-automatic operation
  • Remote communications
  • Load shed from emergency

Optional Delayed Transition includes:

  • Pre-transfer signal with 1 N.O. and 1 N.C. contacts
  • Time delay neutral

Similar New Power Solutions

ATC-300+ CONTROLLER
ATS ATC Breaker / Contactor

ATC-300+ CONTROLLER

Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type: Switch application dependent
Switch Type: Switch application dependent

ATC-800 CONTROLLER
ATS ATC Breaker / Contactor

ATC-800 CONTROLLER

Rating Range: 120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type: Switch application dependent
Switch Type: Switch application dependent

ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch

Rating Range: 200-5000A
Transfer Type: Bypass isolation, Closed transition
Switch Type: Power Breaker

ATC Service Entrance Rated MCCB & Power Breaker Based ATS
ATS ATC Breaker / Contactor

ATC Service Entrance Rated MCCB & Power Breaker Based ATS

Rating Range: 30-5000A
Transfer Type: Open / Closed / Delayed
Switch Type: Molded Case and Power Breaker

ATC Contactor Based Bypass Isolation Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Contactor Based Bypass Isolation Automatic Transfer Switch

Rating Range: 100 to 1200A
Transfer Type: Bypass Isolation
Switch Type: Contactor Based

ATC Power Breaker & Case Switch Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Power Breaker & Case Switch Automatic Transfer Switch

Rating Range: 200 to 5000A
Transfer Type: Open Transition
Switch Type: Power Breaker

ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
ATS ATC Breaker / Contactor

ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch

Rating Range: 30-1000A
Transfer Type: Open transition
Switch Type: Molded Case